16.5 AT^SCTM Set critical operating temperature presentation mode
or query temperature
This command can be used to monitor the temperature of the module.
CAUTION: During the first 15 seconds after start-up, the module operates in an automatic report mode: URCs
can be always displayed regardless of the selected mode
<n>.
Syntax
Test Command
AT^SCTM=?
Response(s)
If parameter <p>= 0:
^SCTM:(list of supported <n>s)
OK
If parameter <p>= 1:
^SCTM:(list of supported <n>s), (range of <temp>in Celsius)
OK
Read Command
AT^SCTM?
Response(s)
If parameter <p>= 0:
^SCTM: <n>, <m>
OK
If parameter <p>= 1:
^SCTM: <n>, <m>, <temp>
OK
Write Command
AT^SCTM=<n>[, <p>]
Response(s)
OK
ERROR
+CME ERROR: <err>
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
SIEMENS