How to ensure safety
Pay attention to the safety instructions
S
Attention!
Do not switch on the HI-SCAN unit, if it has not been operated for a period of 6 months! The X-ray
generators must first be regenerated by a competent service technician! The non-respect of this rule
may lead to the destruction of the X-ray generators!30
A
Warning!
Store the X-ray unit in closed rooms only and do not operate it outdoor! Only operate the unit if the
operating conditions regarding ambient temperature (0°C to 40°C) and humidity of the air (10% to
90%, not condensing) are kept during operation! (In units with extended climatic range, please obtain
the operating conditions from the unit's purchase documents.)
Protect the unit entirely against heavy dirt (dust, waste gas etc.) as well as humidity (rain, snow etc.)
and direct sunlight by appropriate measures! This also applies to units installed in vehicles, special
containers etc. for mobile use! 40
A
Warning!
If other persons are charged with the operation of the HI-SCAN X-ray unit, ensure that they are com-
petent operators who know all the safety instructions and legal and official provisions! Roller and
modular plastic belt conveyors may only be loaded and unloaded by trained staff who are familiar
with the accident prevention regulations!50
A
Warning!
Be absolutely sure that the local mains voltage corresponds to the value indicated on the X-ray unit
type plate and the fusing of the provided mains outlet meets at least the value indicated on the type
plate!
Be also sure that the provided mains outlet is equipped with a protective earth conductor! A connec-
tion without PE conductor is not allowed!
If you connect the unit to the on-board supply system of a vehicle, airplane or ship or to another spe-
cial mains supply, pay attention to the prevailing safety instructions! 60
A
Warning!
Make sure that all available emergency stop keys (F 1-12pp.), the mains plug and the main switch*
at the mains input of the X-ray unit or the mains plug at the mains outlet are accessible during oper-
ation! If required, remove objets that might obstruct the access! 70
A
Warning!
Mechanical and electrical modifications of the X-ray unit may only be performed by a trained service
technician! The regulations and instructions given in the Technical Manual must be adhered to! 80
95587412 01/01/09 © Smiths Heimann
1-5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smiths detection HI-SCAN 7555si and is the answer not in the manual?

Smiths detection HI-SCAN 7555si Specifications

General IconGeneral
BrandSmiths detection
ModelHI-SCAN 7555si
CategoryScanner
LanguageEnglish

Related product manuals