How to set operating options
The default image display
The default image display is the image display that appears upon switching on and after actuating V.
Activate menu item Default image display to have a selection list displayed.
Select the desired function and leave the list with
r.
S
Attention!
If you change the default image display, you should assign the HI-MAT
PLUS
image* display function or,
on X-ray units without HI-MAT
PLUS
system*, one of the HI-CAT image functions to a priority key. Other-
wise, these image displays cannot be used any more during baggage inspections!
Image displays of options the unit is not equipped with, must not be selected! 1490
The zoom settings
In the Image settings menu you can set the Maximum zoom factor and, in addition, enable/disable the Con-
tinuous zoom and the Zoom interpolation on newer units.
Select the corresponding item and set the desired value or enable/disable the corresponding function.
Exit the menu with
r.
The screen saver
To achieve longer life of the monitor screen, you can activate the screen saver. After the set time the screen
will be switched to dark, if the X-ray unit is not used.
In the Image settings select the item Screen saver and
set the time.
Exit the menu with
r.
95587413 01/01/09 © Smiths Heimann
I
With setting 0 the screen saver is deac-
tivated.
2-32

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smiths detection HI-SCAN 7555si and is the answer not in the manual?

Smiths detection HI-SCAN 7555si Specifications

General IconGeneral
BrandSmiths detection
ModelHI-SCAN 7555si
CategoryScanner
LanguageEnglish

Related product manuals