EasyManuals Logo
Home>SolarEdge>Inverter>storedge

SolarEdge storedge User Manual

SolarEdge storedge
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
o
Forbackuppower+SmartEnergyManagement-accordingtouserrequirement
o
Forbackup-only-accordingtobatterymanufacturerrecommendation,ifprovided.
Setting Charge/Discharge Profile + Backup Power
Inthismode,youfirstsetthesystemtocharge/dischargeprofile(fortime-of-usearbitrage)andthelevel
ofchargingthebatteryfromAC.Then,yousetupthelevelofstoredenergytobereservedforbackup.
To set up Charge/Discharge Profile (TOU) + Backup Power:
1. AccesstheEnergy Ctrl.menuasdescribedabove.
2.
SelectTime of Use.TheEnergyManagerscreenchangestodisplaythefollowing:
L i m i t C o n t r o l < D i s >
E n e r g y C t r l < T O U >
S e t C a l e n d a r
S t o r a g e C o n t r o l
3.
FromtheEnergy ManagermenuselectSet Calendar.Thefollowingscreenisdisplayed,showing
optionsforcalendarsetting:
S e r v e r S y n c < D i s >
L o a d S D < N / A >
4.
Dooneofthefollowing:
l Toloadatime-of-usetablefromthemonitoringplatform,referto
http://www.solaredge.us/sites/default/files/storedge_charge_discharge_profile_
programming.pdf.
l Toloadatime-of-usetablefromtheSolarEdgeSDcard(contactSolarEdgeto
obtainit),insertthecardtotheslotlabeled"Card"onthecommunicationboard
andselectLoad SD.Fromthedisplayedlistselectthedirectoryandthetable
(filename).
5.
TosetupthelevelofchargingfromAC,dothefollowing:
a. SelectEnergy Manager èStorage Control.
b.
SelectAC Charge è Enable.AnadditionalmenuisaddedtotheStorEdgeControlmenu:AC
Charge Li<None>
A C C h a r g e < E N >
A C C h a r g e L i < N o n e >
B a c k u p R s v d < N / A >
c.
SelectAC Charge Li è Limit Type,andsetoneofthefollowinglimits:
l Set%PVtoenteralimitasapercentageofyear-to-dateenergyproduction.
l SetkWhtoenterafixedannualenergylimit.
l SetNonetounlimitthecharging.
6.
Tosetaminimumbatterylevelusedforbackup,sothatthebatterywillalwayshaveenergystoredin
casebackuppowerisneeded,selectBackup Rsvdandsettherequiredlevelofreservedenergyas
percentageofthebatterycapacity
o
Forbackuppower+SmartEnergyManagement-accordingtouserrequirement
o
Forbackup-only-accordingtobatterymanufacturerrecommendation,ifprovided.
SolarEdge StorEdge Installation Guide MAN-01-000262-1.2
84
Setting Charge/Discharge Profile + BackupPower