2.
PresstheexternalLCDlightbuttontodisplaythebatterystatusscreen,andcheckthat:
l ThebatteryStateis:Discharging/Charging
l TheSOEpercentageisdecreasing/increasing
l ThePWRvalueisgreaterthan0
B S N : X X X X X X X X X I D : 2 4
S O E : 8 9 % W W W W W P W R : 3 W
T o t a l : < x > W h
S t a t e : D i s c h a r g i n g
3.
TurntheACbackONfromthemaindistributionpanel.Theinvertershouldreconnectloadsbackto
thegrid.
To check Maximize Self-consumption mode:
1. VerifytheinverterON/OFFswitchisON.
2. Turnonasmanyloadssothatconsumptionisgreaterthantheinverter'smaximumACpower.
3. PresstheinverterLCDlightbuttontodisplaytheMeterstatusscreenandcheckthatimportpoweris
greaterthanzero:
I m p o r t M e t e r
S t a t u s : < O K / E r r o r # >
P o w e r [ W ] : x x x x x . x
E n e r g y [ W h ] : X X X X X . X
4. PresstheinverterLCDlightbuttontodisplaytheSmartEnergyManagementandtheBatterystatus
screens,andcheckthat:
o
State=Discharging(assumingconsumption>PVproduction;invertermaximumACpower>PV
production.
o
PWR>0
B S N : X X X X X X X X X I D : 2 4
S O E : 8 9 % W W W W W P W R : 2 W
T o t a l : < X > W h
S t a t e : D i s c h a r g i n g
5.
WhilethePVmodulesareexposedtosunlight,verifythatthebatteryischargingproperly:
a. Minimizeconsumptionbyturningoffalltheloadcircuitbreakers,exceptfortheinverter.
b. IntheinverterLCDcheckthattheMeterstatusscreenisdisplayingimportpowerclosetozero.
c.
PresstheexternalLCDlightbuttontodisplaytheBatterystatusscreen,andcheckthat:
l State=Charging
l SOEpercentageisincreasing
l PWR>0
B S N : X X X X X X X X X I D : 2 4
S O E : 8 9 % W W W W W P W R : 2 W
T o t a l : < x > W h
S t a t e : C h a r g i n g
SolarEdge StorEdge Installation Guide MAN-01-000262-1.2
86
Verifying StorEdge Components Functionality