1I-6 Starting System:
No-Load Performance Test
CAUTION
Before performing the following test, secure
the starter motor to the test bench.
1) Connect a battery and ammeter to the starter motor
as shown.
2) Check that the starter rotates smoothly and steadily
with the pinion moving out. Check that the ammeter
indicates the specified current.
Specified current (No-load performance test)
Within 90 A at 11 V
Starter Motor Components
Z9J0111906003
I9J011190004-01
I9J011190005-01
1 3 5 6 7 8 9
10
4
(a)
2
(b)
12
11 13 14
15 16 17 18
19
20
21 26 24
25
24 23 22 28 27
I9J011190006-02
1. Nut 9. Shift lever 17. Armature 25. Center bracket
2. Bolt 10. Front housing 18. Center cover plate 26. Rubber ring
3. Magnetic switch 11. Screw 19. Internal gear 27. Stopper ring
4. Gasket 12. Through bolt 20. Planetary gear 28. Pinion stopper
5. Spring 13. Rear cover 21. Pinion shaft : 7 Nâ‹…m (0.7 kgf-m, 5.1 lbf-ft)
6. Plunger 14. Thrust washer 22. Pinion : 5.5 Nâ‹…m (0.55 kgf-m, 4.0 lbf-ft)
7. Torsion spring 15. Brush holder 23. E-ring : Apply grease.
8. Rubber packing 16. Yoke 24. Washer