Right Hand Rotation Unit: 3A-5
Propeller / Nut / Cotter Pin Inspection
Z9J0113106010
Refer to “Propeller / Propeller Nut and Cotter Pin
Inspection” in Section 0B (Page 0B-16).
Lower Unit Removal and Installation
Z9J0113106020
Removal
WARNING
!
Always disconnect the battery cable, before
removing lower unit.
1) Shift to “Neutral” position. Remove bolt and trim tab
(1) (if necessary).
2) Remove five bolts (2) and separate gearcase (3)
from driveshaft housing.
NOTE
Before gearcase is removed completely,
disconnect speedometer pick up tube (4)
from gearcase.
Installation
1) Ensure that shift rod (1) is at “Neutral” position.
NOTE
Before installing lower unit assembly, bring
shift to Neutral position by turning shift rod
right or left.
2) Insert two dowel pins (2).
3) Apply water resistant grease to driveshaft and shift
rod splines.
: Grease 99000–25161 (SUZUKI Water
Resistant Grease (250 g))
4) Apply a light coating of suzuki silicone seal to mating
surfaces of gearcase and driveshaft housing.
: Sealant 99000–31120 (SUZUKI Silicone
Seal (50 g))
1
I9J011310021-01
2
3
I9J011310022-01
4
I9J011310023-01
1
I9J011310024-01
2
2
I9J011310025-01
http://SelfFixer.com

Table of Contents

Other manuals for Suzuki DF70A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Suzuki DF70A and is the answer not in the manual?

Suzuki DF70A Specifications

General IconGeneral
BrandSuzuki
ModelDF70A
CategoryOutboard Motor
LanguageEnglish

Related product manuals