5-
12
COOLING SYSTEM
Slowly
heat the container and check the temperature
on
the
thermometer when the thermostat
valve begins to open.
_
Thermostat
valve
opening
temperature:
Approximately
75°C (167"F)
Continue heating the container until the water temperature
is
above
lJU
"C
(H/4
"
/-)
.
When the water temperature reaches
90
°C
(1
94°
F)
, the ther-
mostat
valve should have lifted at least 6.0 mm
(0
.24 in).
~
Thermostat
valve
lift
: over 6.0
mm
at
90°C
(over 0.24 in
at
194°F)
If
the thermostat is faulty in either of these two checks, re-
place
it.
INSTALLATION
I
ns
tall
the
thermostat
in
the
reverse
OllJt:.:r
ur
'~rIlUVi:11.
Pay
at-
tention to the following points.
Apply SUZUKI SUPER GREASE "A" to the rubber seal
on
th
e thermostat.
For
USA
~
99000-25030: SUZUKI SUPER GREASE "A"
For
the
other
countries
~
99000-25010: SUZUKI SUPER GREASE "A"
After installing the thermostat, be sure
to
add engine coolant.
(C:7' 2-15)
6.0 mm
--=~~~
1
t:;;5
lpj
(0.24
in
) "::I
http://www.motorcycle.in.th