5-28
Power Unit
4st 4/5/6 2011
16)Disassembly and Inspection of
Breather Chamber
1. Loosen breather cover mounting screws and then remove
the cover.
2. Remove two breather collars 1 and two wave washers 2,
check the parts, and replace if necessary.
11222
17) Inspection of Lifter
1. Check lifter for bend and wear. Replace if necessary.
3434
aa
aa
3. Attach breather collars 3 and wave washers 4.
Position breather collar so that the hole a is directed as
shown.