Startup
DE EN
■
Reduce safety risks when interconnecting batteries.
■
Counteract negative effects on the entire battery system (loss of capacity, so-
called "drift") caused by interconnection, or capacity changes which arise over
time between batteries.
■
Reduce losses at the contact points.
ADVICE
We recommend providing one charger unit for each battery. Your specialist
dealer will certainly be able to assist you in your selection. During charging,
put the main switch in the cable set to the "OFF" position. This helps to prevent
potential electrolytic corrosion.
ADVICE
As soon as a battery fails, it is recommended also to replace the other batteries.
ADVICE
We stipulate using a land connection in the boat with a galvanic isolator in
accordance with the applicable national requirements (e.g. DIN EN ISO 13297,
ABYC E-11) for charging the batteries.
5.6.2 Connecting the power cables to 2 Torqeedo Power 48-5000
Fig. 45: Wiring diagram for Power 48-5000
5.6.3 Connecting Cruise 10.0 to external batteries
(Gel, AGM, other Lithium batteries)
WARNING!
Danger of injury from overheating.
This can result in severe physical injuries or death.
■
Use only genuine cable sets from Torqeedo, or cables with
at least 95 mm² total copper cable cross-section.
■
Power cables must not be extended and must not be routed in bundles.
page 82 / 113