4.0 Wiring, PWB Layout, Jumpers, and Terminal Connections
4.1 Simple Connection Diagrams
TOSVERT-130G2+
STANDARD CONNECTION
MODEL 2010 TO 2330
MCCB
DBR
L2(S)
L1(R)
L3(T)
PB
PA
T2(V)
T3(W)
T1(U)
OH
OV
POWER
SUPPLY
200VAC, 50Hz
200-230VAC, 60Hz
RST
F
R
ST
CC
FORWARD DRIVE
REVERSE DRIVE
INTERLOCK
DRIVE
SS1
JOG/SS2
AD2/SS3
MULTI-FUNCTION
SIGNAL INPUT
ANALOG INPUT
HAND
AUTO
PP
RR
CC
FRH
AUTO
REFERENCE
-
+
DIGITAL
OPERATION PANEL
P24
MULTI-FUNCTION
SIGNAL OUTPUT
Ry Ry
AM
FM
+
+
AM
FM
FAULT
M
M
4 - 1
MAX.
50mA EACH
100mA TOTAL
IV
GND(E)
FLB
FLC
FLA
RCH/UL
LOW/LL
CC
+24Vdc
RESET
NORMALLY OPEN EXTERNAL
FAULT SIGNAL INPUT
FAULT SIGNAL OUTPUT
OUTPUT FREQUENCY SIGNAL
OUTPUT CURRENT SIGNAL
FULL SCALE AT 1mA