Fig. 38 TCP client work mode
Please follow the following steps to configure connection settings of the work mode for Uart1 port.
1. Click on the “Uart1” tab on the menu frame on the left side of Web UI to go to Uart1 page as shown in Fig.38.
2. For Serial Settings on the Port configuration page, please go to Section 3.1.3.
3. Click on the Socket tab in this page, select TCP Client in the working mode options. Please specify the Destination IP address and
port number of the TCP server program on the remote host. This should match the IP settings of the TCP server program. The default
local port number is 0, M100 will assign a random TCP Port.
4. After finishing configuring the working Mode, please scroll down to the bottom of the page and click on "Save & Apply" button to
save all the changes that you have made. All configurations take effect after a system reboot.
Fig.39 shows an example of test in this mode. By selecting the TCP Client operation mode, a TCP server program on a remote host
computer should be prepared to accept a connection request from the device. In this case,Host IP address is 172.16.14.15.