XES Synergix 8825/8830/8850/8855 & X2-TECH System Introduction 46
8855 & X2-TECH Controller
Status LEDs
AccXES Controllers (UP8 for 8855 and KLF for X2-TECH include 4 status
LEDs used to indicate the following conditions:
Controller Status LEDs
LED Number Color Indicated Condition
LED 1 Green "Ready." Indicates that Controller is powered
up and ready to process incoming jobs.
LED 2 Green "Busy." Indicates that Controller is busy
processing a job.
LED 3 Yellow "Mismatch." Indicates that a media mismatch
has occurred, which may be blocking the print
queue. Also displayed when the Controller's
Accounting Disk is full, or when the Controller
has reached its Accounting record limit.
Check the Web PMT's Main Page to
determine the problem.
LED 4 Red "Attention." Indicates that a Printer or Finisher
fault has occurred. May indicate a paper jam,
out of toner condition, out of media condition,
or a communications problem with one of the
devices.
During power-on self test (POST), the firmware will light LEDs 2, 3, and 4.
After POST has successfully completed, LEDs 2, 3, and 4 will be switched
OFF, and LED 1 will be switched ON. If POST did not successfully complete,
all 4 LEDs will be switched OFF (i.e. they will be unlit).