Chapter4ServiceConguration
CommandMode
Globalcongurationmode
Syntax
setstp{hmd5-digest|hmd5-key}{CISCO|HUAWEI}<0x00..0-0xff..f>
ParameterDescription
ParameterDescription
CISCOItisusedwhenthedeviceconnectstoaCiscodevice.
HUAWEIItisusedwhenthedeviceconnectstoaHuaweidevice.
<0x00..0-0xff..f>
32-bithexadecimalnumeral.0meanstorecoverthedefault
conguration.
4.12.14setstphellotime
Purpose
ThiscommandsetstheintervalforthesendingofSTPmessages.
CommandMode
Globalcongurationmode
Syntax
setstphellotime<1-10>
ParameterDescription
ParameterDescription
<1-10>
Interval(seconds)satisfying:2*(forwarddelay–1)>=agemaxand
agemax>=2*(hellotime+1)
Default
Theintervalis2seconds.
Example
Thefollowingexamplesetstheintervalto1second:
zte(cfg)#setstphellotime1
4-201
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential

Table of Contents

Other manuals for Zte ZXR10 2900E Series

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2900E Series and is the answer not in the manual?

Zte ZXR10 2900E Series Specifications

General IconGeneral
SeriesZXR10 2900E
CategorySwitch
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Ports10/100/1000Base-T
Uplink PortsSFP
Power SupplyAC or DC
Layer SupportLayer 2
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Jumbo Frame9K
VLAN SupportYes

Related product manuals