ZXR102900ESeriesCommandReference
Syntax
setethernet-oamport<portlist>link-monitorframe-secondsthreshold<1-900>window
<10-900>
ParameterDescription
ParameterDescription
<portlist>Portlist
<1-900>Cumulativetime(seconds)ofincorrectframes
<10-900>Timeperiod(seconds)
Guidelines
Theincorrectframecumulativeeventisthecumulativetimeofincorrectframeswithina
speciedtimeperiod.Anincorrectframesummaryeventoccursifthecumulativetime
exceedsthethresholdrulesbytheperiod.
Default
Thecumulativetimeofincorrectframesisonesecond.
Thetimeperiodis60seconds.
Example
Thefollowingexamplesetsthecumulativetimeofincorrectframesto10secondsandthe
timeperiodto50seconds:
zte(cfg)#setethernet-oamport1link-monitorframe-secondsthreshold10window50
4.30.12showethernet-oam
Purpose
ThiscommandshowstheglobalOAMconguration.
CommandMode
Allcongurationmodes
Syntax
showethernet-oam
Example
ThefollowingexampleshowstheglobalOAMconguration:
zte(cfg)#showethernet-oam
EthernetOam:enabled
4-494
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential

Table of Contents

Other manuals for Zte ZXR10 2900E Series

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2900E Series and is the answer not in the manual?

Zte ZXR10 2900E Series Specifications

General IconGeneral
SeriesZXR10 2900E
CategorySwitch
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Ports10/100/1000Base-T
Uplink PortsSFP
Power SupplyAC or DC
Layer SupportLayer 2
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Jumbo Frame9K