4.42.8cfmone-lmsend-packet
Purpose
Thiscommandstartsone-LMdetection.
CommandMode
Globalcongurationmode
Syntax
cfmmd-session<1-16>ma-session<1-32>mep-id<1-8191>one-lmsend-packet[continu
e-time<60-600>interval<1-60>]
ParameterDescription
ParameterDescription
<1-16>MDindex.
<1-32>MAindex.
<1-8191>MEPID,uniquewithinanMA.
<60-600>Durationofone-LMdetection.Thedefaultvalueis60seconds.
<1-60>
Packetsendingintervalofone-LMdetection.Thedefaultvalueis
1second.
Example
Thefollowingexamplestartsone-LMdetectionatthedefaultdetectionintervals:
zte(cfg)#cfmmd-session1ma-session1mep-id1one-lmsend-packet
4.42.9cfmone-lmsend-packetstop
Purpose
Thiscommandstopsone-LMdetection.
CommandMode
Globalcongurationmode
Syntax
cfmmd-session<1-16>ma-session<1-32>mep-id<1-8191>one-lmsend-packetstop
4-570
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential

Table of Contents

Other manuals for Zte ZXR10 2900E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2900E Series and is the answer not in the manual?

Zte ZXR10 2900E Series Specifications

General IconGeneral
SeriesZXR10 2900E
CategorySwitch
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Ports10/100/1000Base-T
Uplink PortsSFP
Power SupplyAC or DC
Layer SupportLayer 2
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Jumbo Frame9K
VLAN SupportYes

Related product manuals