Chapter4ServiceConguration
Syntax
setloopdetecttrunk<trunklist>vlan<vlanlist>{enable|disable}
ParameterDescription
ParameterDescription
<trunklist>Aggregationportlist.
<vlanlist>VLANlist.
enable
EnablesloopdetectiononthespeciedVLANsfortheaggregation
ports.
disable
DisablesloopdetectiononthespeciedVLANsforthe
aggregationports.
Guidelines
Thesetloopdetecttrunkvlanwithenableisusedtoenableloopdetectiononthespecied
VLANsforaggregationports.EachaggregationportcancongureuptoeightVLANs
(exceptPVID).IfdetectiononVLANsisenabledbutdetectiononPVIDisnotenabled,this
commandcanenablethedetectiononPVIDatthesametime.Ifuser-denedVLANIDs
arethesameasPVID,thisoperationisignored.Thesetloopdetecttrunkvlancommand
withdisableisusedtodisableloopdetectiononthespeciedVLANsforaggregationports.
Notethatonlydetectionontheuser-denedVLANIDscanbedisabled.DetectiononPVID
cannotbedisabled.
4.37.9setloopdetecttrunkprotect
Purpose
Thiscommandenablesordisablestrunkportprotectionwhentrunkportloopbackoccurs.
CommandMode
Globalcongurationmode
Syntax
setloopdetecttrunk<trunklist>protect{enable|disable}
ParameterDescription
ParameterDescription
<trunklist>Trunkportlist.
enableBlocksatrunkportwhenloopbackisdetectedontheport.
disable
Activatesanalarmwhenloopbackisdetectedonatrunkport,
withoutblockingtheport.
4-543
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential

Table of Contents

Other manuals for Zte ZXR10 2900E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2900E Series and is the answer not in the manual?

Zte ZXR10 2900E Series Specifications

General IconGeneral
SeriesZXR10 2900E
CategorySwitch
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Ports10/100/1000Base-T
Uplink PortsSFP
Power SupplyAC or DC
Layer SupportLayer 2
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Jumbo Frame9K
VLAN SupportYes