ZXR102900ESeriesCommandReference
4.14.4setqospriority-mappingqos-profiledscp-to-dscp
Purpose
ThiscommandsetsthemappingrelationbetweenDSCPs.
CommandMode
Globalcongurationmode
Syntax
setqospriority-mappingqos-profiledscp-to-dscp<0-63>to<0-63>
ParameterDescription
ParameterDescription
<0-63>(rst)DSCPeld
<0-63>(second)DSCPeldafterremapping
Guidelines
TheDSCPaftermappingcorrespondstotheonebeforemappingonebyone,thatis,0to
0,...,63to63.
Example
ThefollowingexamplesetsDSCPdscpremappingtomap2to20:
zte(cfg)#setqospriority-mappingqos-profiledscp-to-dscp2to20
4.14.5setqospriority-mappingportport-to-profile
Purpose
Thiscommandsetsthecorrespondingrelationbetweenaportandprole.
CommandMode
Globalcongurationmode
Syntax
setqospriority-mappingport<1-28>port-to-profileqos-profile<0-127>
4-302
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential

Table of Contents

Other manuals for Zte ZXR10 2900E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2900E Series and is the answer not in the manual?

Zte ZXR10 2900E Series Specifications

General IconGeneral
SeriesZXR10 2900E
CategorySwitch
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Ports10/100/1000Base-T
Uplink PortsSFP
Power SupplyAC or DC
Layer SupportLayer 2
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Jumbo Frame9K
VLAN SupportYes

Related product manuals