Chapter4ServiceConguration
zte(cfg)#setmldsnoopinghost-time-out300
4.35.8setmldsnpquery-interval
Purpose
Thiscommandsetsthetimeintervalthattheswitchsendsquerymessages.
CommandMode
Globalcongurationmode
Syntax
setmldsnoopingquery-interval<30-65535>
ParameterDescription
ParameterDescription
<30-65535>
Timeintervalthattheswitchsendsquerymessages.Theunit
isseconds.
Default
Thetimeintervalthattheswitchsendsquerymessagesis125seconds.Thetimeout
durationistwicethequerytime,thatis,250seconds.
Example
Thefollowingexamplesetsthetimeintervalthattheswitchsendsquerymessagesto140
seconds:
zte(cfg)#setmldsnoopingquery-interval140
4.35.9setmldsnpquery-response-interval
Purpose
Thiscommandsetsthewaitingtimethattheswitchsendsreportmessages.
CommandMode
Globalcongurationmode
Syntax
setmldsnoopingquery-response-interval<1000-25000>
4-527
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential

Table of Contents

Other manuals for Zte ZXR10 2900E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2900E Series and is the answer not in the manual?

Zte ZXR10 2900E Series Specifications

General IconGeneral
SeriesZXR10 2900E
CategorySwitch
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Ports10/100/1000Base-T
Uplink PortsSFP
Power SupplyAC or DC
Layer SupportLayer 2
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Jumbo Frame9K
VLAN SupportYes

Related product manuals