Chapter5ManagementConguration
Default
ThenumberoftheUDPportusedtosendSFLOWsamplingmessagesis6343.
Example
ThefollowingexamplesetstheIPaddressoftheSFLOWagentto10.40.89.50:
zte(cfg)#setsflowagent-address10.40.89.50
5.7.2setsflowcollector-address
Purpose
ThiscommandsetstheSFLOWcollector.
CommandMode
Globalcongurationmode
Syntax
setsflowcollector-address<A.B.C.D>[udp-port<1-65535>]
ParameterDescription
ParameterDescription
<A.B.C.D>IPaddressoftheSFLOWcollector.
<1-65535>
NumberoftheUDPportusedtosendSFLOWsampling
messages.
Default
ThenumberoftheUDPportusedtosendSFLOWsamplingmessagesis6343.
Example
ThefollowingexamplesetstheIPaddressoftheSFLOWcollectorto10.40.89.78:
zte(cfg)#setsflowcollector-address10.40.89.78
5.7.3setsflowversion
Purpose
ThiscommandsetstheformatversionofSFLOWsamplingmessages.
CommandMode
Globalcongurationmode
5-61
SJ-20130731155059-003|2013-11-27(R1.0)ZTEProprietaryandCondential

Table of Contents

Other manuals for Zte ZXR10 2900E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zte ZXR10 2900E Series and is the answer not in the manual?

Zte ZXR10 2900E Series Specifications

General IconGeneral
SeriesZXR10 2900E
CategorySwitch
Operating Temperature0°C to 45°C
Storage Temperature-40°C to 70°C
Ports10/100/1000Base-T
Uplink PortsSFP
Power SupplyAC or DC
Layer SupportLayer 2
Operating Humidity10% to 90% non-condensing
Storage Humidity5% to 95% non-condensing
Jumbo Frame9K
VLAN SupportYes