Page #52 background imageLoading...
Page #52 background image
ACS 600 MultiDrive Technical Data
A-28 ACS 600 MultiDrive
Braking Section DC
Fuses
The d.c. fuses (Bussmann) for the braking sections are listed below.
Dynamic Braking Section
Fuse
U
N
(V)
I
N
(A)
Pre-arching
Integral
(A
2
s)
Type Size
400 V Range
ACA 621-0210-3 10001250 400 23000 170M 5142 2/110
ACA 621-0320-3...-1920-3 10001250 630 115000 170M 5146 2/110
ACA 622-0210-3 10001250 400 23000 170M 5142 2/110
ACA 622-0320-3...-1920-3 10001250 630 115000 170M 5146 2/110
500 V Range
ACA 621-0260-5 10001250 400 23000 170M 5142 2/110
ACA 621-0400-5...-2400-3 10001250 630 115000 170M 5146 2/110
ACA 622-0260-5 10001250 400 23000 170M 5142 2/110
ACA 622-0400-5...-2400-5 10001250 630 115000 170M 5146 2/110
690 V Range
ACA 621-0400-6...-2400-6 10001250 630 115000 170M 5146 2/110
ACA 622-0400-6...-2400-6 10001250 630 115000 170M 5146 2/110
PDM code 00025310-A

Table of Contents