58 Start-up and control with I/O
Check the installation. See the checklist in chapter Installation checklist on page
55.
How you start up the drive depends on the control panel you have, if any.
If you have no control panel, follow the instructions given in section How to start
up the drive without a control panel on page 58.
If you have a Basic control panel (ACS-CP-S), follow the instructions given in
section How to perform a manual start-up on page 59.
If you have an Assistant control panel (ACS-CP-A or ACS-CP-D), you can
either run the Start-up assistant (see section How to perform a guided start-up on
page 62) or perform a manual start-up (see section How to perform a manual
start-up on page 59).
The Start-up assistant, which is included in the Assistant control panel only,
guides you through all essential settings to be done. In the manual start-up, the
drive gives no guidance; you go through the very basic settings by following the
instructions given in section How to perform a manual start-up on page 59.
How to start up the drive without a control panel
POWER-UP
Apply input power and wait for a moment.
Check that the red LED is not lit and the green LED is lit but not blinking.
The drive is now ready for use.
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
sales@aotewell.com
+86-755-8660-6182

Table of Contents

Other manuals for ABB ACS310

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS310 and is the answer not in the manual?

ABB ACS310 Specifications

General IconGeneral
BrandABB
ModelACS310
CategoryDC Drives
LanguageEnglish

Related product manuals