Program features 133
Custom U/f ratio
The user can define a U/f curve (output voltage as a function of frequency). This
custom ratio is used only in special applications where linear and squared U/f ratio
are not sufficient (eg when motor break-away torque needs to be boosted).
Note: The voltage and the frequency points of the U/f curve must fulfill the following
requirements:
2610 < 2612 < 2614 < 2616 < 2618 and
2611 < 2613 < 2615 < 2617 < 9907
WARNING! High voltage at low frequencies may result in poor performance or
motor damage (overheating).
Settings
Diagnostics
Parameter Additional information
2605 Custom U/f ratio activation
26102618 Custom U/f ratio settings
Fault Additional information
PAR USER DEFINED U/F Incorrect U/f ratio
f (Hz
)
Custom U/f ratio Voltage (V)
Par. 2618
Par. 2616
Par. 2614
Par. 2612
Par. 2610
Par. 2603
Par. 2611 Par. 2613 Par. 2615 Par. 2617 Par. 9907
Aotewell Ltd
www.aotewell.com
Industry Automation
HongKong|UK|China
sales@aotewell.com
+86-755-8660-6182

Table of Contents

Other manuals for ABB ACS310

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS310 and is the answer not in the manual?

ABB ACS310 Specifications

General IconGeneral
BrandABB
ModelACS310
CategoryDC Drives
LanguageEnglish

Related product manuals