Control panels 93
Changed parameters mode
In the Changed parameters mode, you can:
• view a list of all parameters that have been changed from the macro default
values
• change these parameters
• start, stop, change the direction and switch between local and remote control.
How to view and edit changed parameters
Step Action Display
1. Go to the Main menu by pressing if you are in the
Output mode, otherwise by pressing repeatedly until
you get to the Main menu.
2. Go to the Changed parameters mode by selecting
CHANGED PAR on the menu with keys and ,
and pressing .
3. Select the changed parameter on the list with keys
and . The value of the selected parameter is shown
below it. Press to modify the value.
4. Specify a new value for the parameter with keys
and .
Pressing the key once increments or decrements the
value. Holding the key down changes the value faster.
Pressing the keys simultaneously replaces the displayed
value with the default value.
5. • To accept the new value, press . If the new value
is the default value, the parameter is removed from the
list of changed parameters.
• To cancel the new value and keep the original, press
.
PARAMETERS
ASSISTANTS
CHANGED PAR
EXIT ENTER
00:00
LOC
MAIN MENU 1
1202 CONST SPEED 1
10.0 Hz
1203 CONST SPEED 2
1204 CONST SPEED 3
9902 APPLIC MACRO
EXIT EDIT
00:00
LOC
CHANGED PAR
1202 CONST SPEED 1
CANCEL SAVE
00:00
LOC
10.0 Hz
PAR EDIT
1202 CONST SPEED 1
CANCEL SAVE
00:00
LOC
15.0 Hz
PAR EDIT
1202 CONST SPEED 1
15.0 Hz
1203 CONST SPEED 2
1204 CONST SPEED 3
9902 APPLIC MACRO
EXIT EDIT
00:00
LOC
CHANGED PAR