AWT420 | UNIVERSAL 4-WIRE, DUAL-INPUT TRANSMITTER | OI/AWT420-EN REV. B
53
pH/Redox/ORP
Menu Comment Default
Tag 
Operator Pages.

Measurement Type Select measurement type:
pH/Redox/ORP
Note. If a change is made the I/O sources are reset.
pH
Range High Set the span value used in Chart and Bargraph views. 
Range Low Set the zero value used in Chart and Bargraph views. 
Filter Type Select the signal filtering type:
None/Low/Medium/High
None
Note. The following menus are displayed only if Measurement TypepH.
Temp. Compensation Set the type of temperature compensation:
Manual/Automatic/Auto solution
Automatic
Solution Coeff. NoteTemp. Compensation Auto solution.

See Appendix A, .
N/A
Manual Temperature Note. Temp. CompensationManual.

N/A
Note. The following menus are displayed only if Measurement TypeRedox/ORP.
Temperature Sensor Set the type of temperature measurement:
Manual/Automatic
Note. If Temperature SensorManual, the temperature value is not displayed in the associated
Operator page or Signals View.
N/A
Low Slope Limit A pH probe degrades over time. As this happens the slope calculated by a calibration procedure gradually
decreases. Set the slope value below which a calibration fails. The low slope warning diagnostic is


Sensor Diagnostics
Broken Glass Note: Measurement Type pH.



Out Of Solution 


Ref. Poisoning Note: 



Ref. Failure Note: 



Ref. Blocked 


Ref. Alarm Limit Note: Ref. Blocked sensor diagnostic is Enabled.
A blocked reference electrode is detected when the impedance of the reference electrode exceeds
a given limit. Set the impedance value above which the reference blocked diagnostic is activated.
N/A
Reset To Defaults Select to reset all Sensor Setup parameters to their default values.

Table of Contents

Other manuals for ABB AWT420

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB AWT420 and is the answer not in the manual?

ABB AWT420 Specifications

General IconGeneral
BrandABB
ModelAWT420
CategoryTransmitter
LanguageEnglish

Related product manuals