4 Repair
4.6.4. Replacement of motor, axis 4
3HAC022033-001 Revision: K354
© Copyright 2004-2011 ABB. All rights reserved.
4. Remove the motor unit, according to step 4 to 12
in section Removal, motor axis 4 on page 349.
5. Fill the four screw recesses on the new motor with
Sikaflex. (After hardening, Sikaflex can be formed
with a knife)
xx0600002875
• A: Motor unit
• B: Sikaflex in screw
recesses
6. Continue to refit the new motor according to
section, Refitting, motor axis 4 on page 351.
7. Perform a leak test according to Inspection of air
hoses (Foundry Prime) on page 191.
Action Note
Continued