35
Parametric EQ
A parametric equalizer is a multi-band variable equalizer that allows control of frequency
amplitude (boost/cut), center frequency, and frequency bandwidth, or Q.
The parametric equalizer settings for your device allows you to adjust the Q and gain for
se
ven separate frequencies, which then become plot points on the screen’s graph.
Attack Sets how long it takes for the gate to open once the signal
re
aches the threshold level.
Attack range is 1 to 500 ms.
Hold Sets the length of time the gate will stay fully open after
th
e signal reaches the threshold level.
Hold range is 1 to 500 ms.
Decay Sets hows quickly or slowly the gate will close once the
si
gnal has dropped below the threshold level and the Hold
in
terval has expired.
Decay range is 0 to 2000 ms.
Figure 16. Parametric Equalizer Settings
Table 15. Noise Gate Settings