51
2 Select the Menu button for the channel.
3 From the drop-down menu, select Status.
The view only information that appears is described in the following table:
Table 21. Status
Switch Position Indicates the position of the Amplifier Mode switch
located on the rear of the appliance. Bridged mode is typi-
cally used when higher-power, single-channel operation
with a high-impedance loudspeaker load is needed. For
information about setting the Amplifier Mode, refer to the
installation manual for the appliance.
Thermal Protect Appears red if the output channel is being overloaded or
there is an external short and the amplifier has placed
itself into protection mode to prevent permanent damage.
Otherwise, the LED is green.
Channel 1/2 Output
Limit
Appears red if the output signal is too high and is being
clipped or distorted. Otherwise, the LED is green.
Temperature Provides the real-time temperature of the appliance in
both Celsius and Fahrenheit. The amplifier enters protec-
tion mode if the temperature exceeds 85 °C.
Standby Indicates if channels A/B are in Standby mode (On) or not
(Off).
Mute Indicates if channels A/B are in Mute mode (On) or not
(Off).