en | B92x/B91x Actions menu Control Panels
2019.06 | 07 | F.01U.307.371 Bosch Security Systems B.V.
26.3 Test
Use the Test menu to walk test your system, send test reports, or to
review system revision information on the keypad display.
26.3.1 Walk Test
A walk test allows you to test the sensors, keypads, sounders, and other
devices in your system without creating alarm events. You can review
untested points at the keypad to help pinpoint any problems.
You cannot turn on the security system while in the walk test mode.
Also, the security system does not create alarm events for points
included in the walk test. Points not included create alarm events. For
example, faulting a fire point during an intrusion walk test creates a fire
alarm event.
Beginning the walk test activates the burglary tone for 2 seconds. A
battery test also begins. A successful battery test ends in four minutes
(the walk test continues). If the security system determines there is a
low battery, it generates a low battery event and continues the test. If
the battery is determined to be very low, the system creates a missing
battery event and ends the battery test immediately.
To test individual detection devices, simply activate sensors and open
protected doors and windows one-at-a-time. As you fault each detection
device, the keypad from which you initiated the test emits a brief tone,
and for 60 seconds the display indicates that the point was tested. The
tone and display verify that each detection device is working properly.
Keypads within the area’s scope from which you did not initiate the
walk test show Walk test in progress during the testing.

Table of Contents

Other manuals for Bosch B9512G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B9512G and is the answer not in the manual?

Bosch B9512G Specifications

General IconGeneral
ModelB9512G
ManufacturerBosch
CompatibilityBosch Security Systems
Number of Zones599
Keypads32
Communication FormatsContact ID, SIA
Input Voltage16.5 VAC
Battery Backup7 Ah
Operating Temperature0°C to +49°C (32°F to +120°F)