24
SMALL
C1
NO1
NO2
NO3
C1
C4
NO4
NO5
NO6
C4
C7
NO7
C7
NO8
C8
NC8
G
G0
U1
U2
U3
GND
+VDC
U4
GND
U5
GND
VG
VG0
Y1
Y2
Y3
Y4
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
IDC1
J1
J2
J3
J4
J5
J14
J10
J13
J12
J15
drac SMBdrac suBdleiF
4321
Tx/Rx
J11 pLAN
GND
J25 BMS2
Tx/Rx
GND
Tx/Rx
GND
J26 FBus2
+Vterm
GND
+5VREF
J24
+
XXXXXXXXXXXX
26
25
18
17
12
1327 14
Mac address
15
16
10
11
4
5
1
6
2
3 3 7
8
28
C1
NO1
NO2
NO3
C1
C4
NO4
NO5
NO6
C4
C7
NO7
C7
NO8
C8
NC8
G
G0
U1
U2
U3
GND
+VDC
U4
GND
U5
GND
VG
VG0
Y1
Y2
Y3
Y4
ID1
ID2
ID3
ID4
ID5
ID6
ID7
ID8
IDC1
J1
J2
J3
J4
J5
J14
J10
J13
J12
J15
drac SMBdrac suBdleiF
4321
Tx/Rx
J11 pLAN
GND
J25 BMS2
Tx/Rx
GND
Tx/Rx
GND
J26 FBus2
+Vterm
GND
+5VREF
J24
+
XXXXXXXXXXXX
NO12
C12
NC12
NO13
C13
NC13
C9
NO9
NO10
NO11
C9
U6
U7
U8
GND
ID9
ID10
ID11
ID12
IDC9
ID13H
ID13
IDC13
ID14
ID14H
J7
J8
J16
J17
J18
J6
8 9
MEDIUM
15
3
26
25
18
17
12
1327 14
Mac address
15
16
10
11
4
5
1
6
2
3 3 7
8
28
ENG
c.pCO sistema +0300057EN rel. 1.2 - 29.05.2017
4.1 c.pCO Small and Medium: connection terminals
Fig. 4.u
Key:
Ref. Description Ref. Description
1 Power conncetion G(+), G0(-) 12 Reserved
2
+Vterm: power supply for additional terminal
+5 VREF power supply for ratiometric probes
13 Ethernet port 1
3 Universal inputs/outputs 14 Ethernet port 2
4 +VDC: power supply for active probes 15 Relay digital outputs
5 Button for setting pLAN address, second display, LED 16 BMS2 port
6
VG: power supply at voltage A(*) for opto-isolated analogue output
VG0: power to optically-isolated analogue output, 0 Vac/Vdc
17 FieldBus2 port
7 Analogue outputs 18 Jumpers for selecting FieldBus/ BMS
8 ID: digital inputs for voltage A (*) 25 USB Host Port (Master)
9
ID..: digital inputs for voltage A (*)
IDH..: digital inputs for voltage B (**)
26 USB Device Port (Slave)
10 pLAN telephone connector for terminal 27 Faston for earth connection to Ethernet Port
11 pLAN plug-in connector 28 Display built-in and keypad
(*) Tensione A: 24 Vac o 28...36 Vdc; (**) Tensione B: 230 Vac - 50/60 Hz.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Carel c.pCO and is the answer not in the manual?

Carel c.pCO Specifications

General IconGeneral
BrandCarel
Modelc.pCO
CategoryController
LanguageEnglish

Related product manuals