OBRGetRSSExpandedOption
: Retrieves decode options of RSS Expanded
symbology.
OBRSetRSS14StackedOption
: Sets up scanning with RSS-14 Stacked symbology.
OBRGetRSS14StackedOption
: Retrieves decode options of RSS-14 Stacked
symbology.
OBRSetRSSExpandedStackedOption
: Sets up scanning with RSS Expanded Stacked
symbology.
OBRGetRSSExpandedStackedOption
: Retrieves decode options of RSS Expanded Stacked
symbology.
Validation
Validation is carried out for a specified number of times in the range of 1 to 9 (Default = 3) to
check if scanned data is valid, and then the data is output. The number of validations can be set
either at the Control Panel or using the Laser Scanner Library.
The functions of the Laser Scanner Library relevant to the Validation are as follows.
OBRSetCheckCounter
: Sets up the no. of validations for decoding data.
OBRGetCheckCounter
: Retrieves the no. of validations for decoding data.
No. of Scanning Times
In “Continuous Scanning” mode, scanning continues for the preset number of scanning times in
the range of 1 to 9 (Default = 1) and then it will stop in waiting mode. The number of times for
scanning can be set either at the Control Panel or using the Laser Scanner Library.
The functions of the Laser Scanner Library relevant to the “No. of Scanning Times” are as
follows.
OBRSetScanningCounter
: Sets up the no. of times for continuous scanning.
OBRGetScanningCounter
: Retrieves the no. of times for continuous scanning.
Scanning Period
Valid time period of scanning in the range of 1 to 9 (Default = 3) seconds after Trigger key was
pressed down can be set either at the Control Panel or using the Laser Scanner Library. After the
preset time has elapsed, the scanner goes into standby mode waiting for the Trigger key to be
pressed down again.
The functions of the Laser Scanner Library relevant to the Scanning Period are as follows.
OBRSetScanningTimeout
: Sets up a time period of timeout for scanning complete.
OBRGetScanningTimeout
: Retrieves the timeout of scanning complete.
Double Scanning Prevention
This prevents scanning the same bar code twice while the “Continuous Scanning” mode has been
set. Scanning the same bar code again is prohibited while the scanning continues for the preset
number of times. However, the bar code can be scanned again when the “Continuous Scanning”
newly starts.