Configuration File
The various setting values can be stored in a file and resumed. The setting file storage location and
its name are ā€œ\Documents and Settings\System Settings\OBRDRV.iniā€. If there is no such the
setting file, the default values are used to initiate the scanning.
Table 2.47
Symbol
ogy
Parameter Description Range Default Setting
1 1: Enable Code39
22: Enable NW-7
4 4: Enable WPC Addon
88: Enable WPC
16 16: Enable UPC-E Addon
32 32: Enable UPC-E
64 64: Enable IDF
128 128: Enable ITF
256 256: Enable Code93
512 512: Enable Code128
1024 1024: Enable MSI
2048 2048: Enable IATA
4096 4096: Enable GS1 DataBar
Omnidirectional.
8192 8192: Enable GS1 DataBar
Limited.
16384 16384: Enable GS1 DataBar
Expanded.
32768 32768 Enable GS1 DataBar
Stacked.
Readable Bar Code
READCODE Enable or disable
scanning the
symbologies.
(note 1)
65536
131071
65536 Enable GS1 DataBar
Expanded Stacked.
CODE39_MIN Valid minimum digits 2 2
CODE39_MAX Valid maximum digits 52 52
0 0: With start and stop
characters
1 1: Without start and stop
characters
2 2: With Full ASCII conversion
With start and stop
characters
CODE39_OUTFORMAT Output format
3
0
3: With Full ASCII conversion.
Without start and stop
characters.
00: Disable CODE39_CHKD Check digit calculation
1
0
1: Enable
00: Disable
CODE 39 Option
CODE39_CHKCH Check character output
1
1
1: Enable
Continue.

Table of Contents

Other manuals for Casio DT-X8 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio DT-X8 Series and is the answer not in the manual?

Casio DT-X8 Series Specifications

General IconGeneral
BrandCasio
ModelDT-X8 Series
CategoryTouch terminals
LanguageEnglish

Related product manuals