85
2.3.4 Scan Result Notification
The notification of the read completion of a symbol can be posted using one of the following two
integrated devices. The buzzer sound level can be set up at the Control Panel.
Table 2.55
Device Setting Read succeeded Read failed
Read terminated
(release the Trigger key)
Remark
Mode 1 Lit in green Lit in red None Default
Mode 2 Lit in green None None
LED
Invalid None None None
Valid Sound None None Default
Buzzer
Invalid None None None
Valid Vibrates No No
Vibrator
Invalid No No No
Valid
The functions of the Imager Library relevant to the Scan Result Notification are as follows.
IMGSetLED
: Sets up notification via LED for scanning complete.
IMGGetLED
: Retrieves the notification via LED for scanning complete.
IMGSetBuzzer
: Sets up notification via buzzer for scanning complete.
IMGGetBuzzer
: Retrieves the notification via buzzer for scanning complete.