Section 10: Balancing Walk-through
154
Step 5. Trim Balance
Replace safety covers, start the machine again and let the
rotor settle to its normal operating speed.
Press
to perform a Trim Balance.
After a few seconds the instrument displays the vibration level with
the imbalance corrected.
Press to return to the Balance Menu.
The instrument will now display the details of additional weight
adjustments required to trim-balance the rotor (i.e. to further reduce
the level of vibration/imbalance). You can end balancing at this point
or continue with another reposition of trim balance weights, as
indicated, to improve on the balance level. The trim balance process
can be repeated until you are satisfied with the results. When you
have finished, press
to return to the Balancing Menu.
You may wish to check that the residual imbalance meets
machine-balancing standards such as ISO 1940 and ISO
2372. The instrument includes an ISO 1940 calculator
should you wish to check the residual imbalance. To access
this, from the Balancing Menu press
Balance Weight
Calculations.
To review measurement and weight adjustment details at
various stages of the balancing process, press
Review
Readings from the Balancing Menu.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Commtest Instruments vb2000 and is the answer not in the manual?

Commtest Instruments vb2000 Specifications

General IconGeneral
BrandCommtest Instruments
Modelvb2000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals