3.6.4 LCP Menu
Quick Menus
The Quick Menus mode provides a list of menus used to congure and operate the drive. Select the Quick Menus mode by pressing
the [Quick Menu] key. The resulting readout appears on the LCP display.
e30bf241.10
Q1 My Personal Menu
Q2 Quick Setup
Q3 Function Setups
Q4 Smart Start
0.0% 0.00
Quick Menus
1(1)
Illustration 10: Quick Menu View
Q1 My Personal Menu
The Personal Menu is used to determine what is shown in the display area. Refer to
3.6.3 Local Control Panel (LCP). This menu can
also show up to 50 pre-programmed parameters. These 50 parameters are manually entered using parameter 0-25 My Personal
Menu.
Q2 Quick Setup
The parameters found in the Q2 Quick Setup contain basic system and motor data that are always necessary for conguring the
drive. See
7.2.4 Entering System Information for the set-up procedures.
Q3 Function Setups
The parameters found in the Q3 Function Setups contain data for fan, compressor, and pump functions. This menu also includes
parameters for LCP display, digital preset speeds, scaling of analog references, closed-loop single-zone, and multizone applications.
Q4 Smart Setup
Q4 Smart Setup guides the user through typical parameter settings used to congure 1 of the following 3 applications:
Mechanical brake.
Conveyor.
Pump/fan.
The [Info] key can be used to see help information for various selections, settings, and messages.
Q5 Changes Made
Select Q5 Changes Mode for information about:
The 10 most recent changes.
Changes made from default setting.
Q6 Loggings
Use Q6 Loggings for fault nding. To get information about the display line readout, select Loggings. The information is shown as
graphs. Only parameters selected in parameter 0-20 Display Line 1.1 Small through parameter 0-24 Display Line 3 Large can be viewed.
It is possible to store up to 120 samples in the memory for later reference.
Table 38: Logging Parameter Examples
Q6 Loggings
Parameter 0-20 Display Line 1.1 Small
Reference [%]
Parameter 0-21 Display Line 1.2 Small
Motor Current [A]
Parameter 0-22 Display Line 1.3 Small
Power [kW]
Parameter 0-23 Display Line 2 Large
Frequency
Parameter 0-24 Display Line 3 Large
kWh Counter
Main Menu
The Main Menu mode is used to:
AQ357954340588en-000201 / 130R088132 | Danfoss A/S © 2020.09
Product Overview
VLT® Refrigeration Drive FC 103
Operating Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 102 N250 and is the answer not in the manual?

Danfoss VLT FC 102 N250 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 102 N250
CategoryDC Drives
LanguageEnglish

Related product manuals