6.3.3 1-** Load/Motor
Par. No. # Parameter description Default value 4-set-up FC 302
only
Change
during
operation
Conver-
sion
index
Type
1-0* General Settings
1-00 Configuration mode null All set-ups TRUE - Uint8
1-01 Motor control principle null All set-ups FALSE - Uint8
1-02 Flux motor feedback source [1] 24V encoder All set-ups FALSE - Uint8
1-03 Torque characteristics [0] Constant torque All set-ups x TRUE - Uint8
1-04 Overload mode [0] High torque All set-ups FALSE - Uint8
1-05 Local mode configuration [2] As mode par 1-00 All set-ups TRUE - Uint8
1-06 Clockwise direction [0] Normal All set-ups FALSE - Uint8
1-1* Motor Selection
1-10 Motor construction [0] Asynchron All set-ups FALSE - Uint8
1-2* Motor Data
1-20 Motor power [kW] App.Dependent All set-ups FALSE 1 Uint32
1-21 Motor power [HP] App.Dependent All set-ups FALSE -2 Uint32
1-22 Motor voltage App.Dependent All set-ups FALSE 0 Uint16
1-23 Motor frequency App.Dependent All set-ups FALSE 0 Uint16
1-24 Motor current App.Dependent All set-ups FALSE -2 Uint32
1-25 Motor nominal speed App.Dependent All set-ups FALSE 67 Uint16
1-26 Motor cont. rated torque App.Dependent All set-ups FALSE -1 Uint32
1-28 Motor rotation check [0] Off All set-ups FALSE Uint8
1-29 Automatic motor adaptation (AMA) [0] Off All set-ups FALSE - Uint8
1-3* Adv. Motor Data
1-30 Stator resistance (Rs) App.Dependent All set-ups FALSE -4 Uint32
1-31 Rotor resistance (Rr) App.Dependent All set-ups FALSE -4 Uint32
1-33 Stator leakage reactance (X1) App.Dependent All set-ups FALSE -4 Uint32
1-34 Rotor leakage reactance (X2) App.Dependent All set-ups FALSE -4 Uint32
1-35 Main reactance (Xh) App.Dependent All set-ups FALSE -4 Uint32
1-36 Iron loss resistance (Rfe) App.Dependent All set-ups FALSE -3 Uint32
1-37 d-axis inductance (Ld) App.Dependent All set-ups x FALSE -4 Int32
1-39 Motor poles App.Dependent All set-ups FALSE 0 Uint8
1-40 Back EMF at 1000 RPM App.Dependent All set-ups x FALSE 0 Uint16
1-41 Motor angle offset 0 N/A All set-ups FALSE 0 Int16
1-5* Load Indep. Setting
1-50 Motor magnetisation at zero speed 100 % All set-ups TRUE 0 Uint16
1-51 Min speed normal magnetising [RPM] App.Dependent All set-ups TRUE 67 Uint16
1-52 Min speed normal magnetising [Hz] App.Dependent All set-ups TRUE -1 Uint16
1-53 Model shift frequency App.Dependent All set-ups x FALSE -1 Uint16
1-54 Voltage reduction in fieldweakening 0 V All set-ups FALSE 0 Uint8
1-55 U/f characteristic - U App.Dependent All set-ups TRUE -1 Uint16
1-56 U/f characteristic - F App.Dependent All set-ups TRUE -1 Uint16
1-58 Flystart test pulses current 30 % All set-ups FALSE 0 Uint16
1-59 Flystart test pulses frequency 200 % All set-ups FALSE 0 Uint16