6.3.3 1-** Load/Motor
Par. No. # Parameter description Default value 4-set-up FC 302
only
Change
during
operation
Conver-
sion
index
Type
1-0* General Settings
1-00 Configuration mode null All set-ups TRUE - Uint8
1-01 Motor control principle null All set-ups FALSE - Uint8
1-02 Flux motor feedback source [1] 24V encoder All set-ups FALSE - Uint8
1-03 Torque characteristics [0] Constant torque All set-ups x TRUE - Uint8
1-04 Overload mode [0] High torque All set-ups FALSE - Uint8
1-05 Local mode configuration [2] As mode par 1-00 All set-ups TRUE - Uint8
1-06 Clockwise direction [0] Normal All set-ups FALSE - Uint8
1-1* Motor Selection
1-10 Motor construction [0] Asynchron All set-ups FALSE - Uint8
1-2* Motor Data
1-20 Motor power [kW] App.Dependent All set-ups FALSE 1 Uint32
1-21 Motor power [HP] App.Dependent All set-ups FALSE -2 Uint32
1-22 Motor voltage App.Dependent All set-ups FALSE 0 Uint16
1-23 Motor frequency App.Dependent All set-ups FALSE 0 Uint16
1-24 Motor current App.Dependent All set-ups FALSE -2 Uint32
1-25 Motor nominal speed App.Dependent All set-ups FALSE 67 Uint16
1-26 Motor cont. rated torque App.Dependent All set-ups FALSE -1 Uint32
1-28 Motor rotation check [0] Off All set-ups FALSE Uint8
1-29 Automatic motor adaptation (AMA) [0] Off All set-ups FALSE - Uint8
1-3* Adv. Motor Data
1-30 Stator resistance (Rs) App.Dependent All set-ups FALSE -4 Uint32
1-31 Rotor resistance (Rr) App.Dependent All set-ups FALSE -4 Uint32
1-33 Stator leakage reactance (X1) App.Dependent All set-ups FALSE -4 Uint32
1-34 Rotor leakage reactance (X2) App.Dependent All set-ups FALSE -4 Uint32
1-35 Main reactance (Xh) App.Dependent All set-ups FALSE -4 Uint32
1-36 Iron loss resistance (Rfe) App.Dependent All set-ups FALSE -3 Uint32
1-37 d-axis inductance (Ld) App.Dependent All set-ups x FALSE -4 Int32
1-39 Motor poles App.Dependent All set-ups FALSE 0 Uint8
1-40 Back EMF at 1000 RPM App.Dependent All set-ups x FALSE 0 Uint16
1-41 Motor angle offset 0 N/A All set-ups FALSE 0 Int16
1-5* Load Indep. Setting
1-50 Motor magnetisation at zero speed 100 % All set-ups TRUE 0 Uint16
1-51 Min speed normal magnetising [RPM] App.Dependent All set-ups TRUE 67 Uint16
1-52 Min speed normal magnetising [Hz] App.Dependent All set-ups TRUE -1 Uint16
1-53 Model shift frequency App.Dependent All set-ups x FALSE -1 Uint16
1-54 Voltage reduction in fieldweakening 0 V All set-ups FALSE 0 Uint8
1-55 U/f characteristic - U App.Dependent All set-ups TRUE -1 Uint16
1-56 U/f characteristic - F App.Dependent All set-ups TRUE -1 Uint16
1-58 Flystart test pulses current 30 % All set-ups FALSE 0 Uint16
1-59 Flystart test pulses frequency 200 % All set-ups FALSE 0 Uint16
Programming Operating Instructions
MG37A202 Danfoss A/S © Rev. 2014-07-29 All rights reserved. 75
6 6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 302 and is the answer not in the manual?

Danfoss VLT FC 302 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 302
CategoryController
LanguageEnglish

Related product manuals