Scanning Features
Product Reference Guide 31
Scanning Features
Scan Mode
Selects the scan operating mode for the reader. Selections are:
Trigger Single —
When the trigger is pulled, scanning is activated until one of the fol-
lowing occurs:
- Scanning Active Time has elapsed
- a label has been read
- the trigger is released
This mode is associated with typical handheld reader operation: when the trigger is
pulled, scanning starts and the product scans until the trigger is released, or a label is read,
or the maximum Scanning Active Time has elapsed.
Trigger Hold Multiple —
When the trigger is pulled, scanning starts and the product
scans until the trigger is released or Scanning Active Time has elapsed. Reading a label does
not disable scanning. Double Read Timeout prevents undesired multiple reads of the same
label while in this mode.
Trigger Pulse Multiple —
When the trigger is pulled, continuous scanning is activated
until Scanning Active Time has elapsed or the trigger has been released and pulled again.
Double Read Timeout
1
prevents undesired multiple reads of the same label while in this
mode.
Flashing —
The reader flashes
1
on and off regardless of the trigger status. Flash rate is
controlled by Flash On Time and Flash Off Time. When Flash is ON the reader reads con-
tinuously, when Flash is OFF scanning is deactivated.
Always On —
No trigger pull is required to read a barcode. Scanning is continually on.
If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read
Timeout
1
prevents undesired multiple reads of the same label while in this mode.
Stand Mode —
No trigger pull is required to read a barcode. Scanning is turned on au-
tomatically when an item is placed in reader’s field of view. If the trigger is pulled, the
reader acts as if it in single read mode. Double Read Timeout
1
prevents undesired multiple
reads of the same label while in this mode.
Trigger Object Sense —
This mode is similar to Stand Mode, except that a trigger pull
is required to activate the decoder.
1. Controlled by Flash On Time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Powerscan PD7100 and is the answer not in the manual?

Datalogic Powerscan PD7100 Specifications