EasyManuals Logo

Dell PowerEdge T20 User Manual

Dell PowerEdge T20
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
6. If the problem is not resolved, proceed to the next step to begin troubleshooting the other USB devices attached to
the system.
7. Power down all attached USB devices and disconnect them from the system.
8. Reboot the system and, if your keyboard is functioning, enter the System Setup. Verify that all USB ports are
enabled on the
Integrated Devices screen, in the System Setup options.
If your keyboard is not functioning, you can also use remote access. If the system is not accessible, reset the
NVRAM_CLR jumper inside your system and restore the BIOS to the default settings.
9. Reconnect and power on each USB device one at a time.
10. If a device causes the same problem, power down the device, replace the USB cable with a known good cable, and
power up the device.
If all troubleshooting fails, see Getting Help.
Troubleshooting A Serial I/O Device
1. Turn off the system and any peripheral devices connected to the serial port.
2. Swap the serial interface cable with a working cable, and turn on the system and the serial device.
If the problem is resolved, replace the interface cable with a known good cable.
3. Turn off the system and the serial device, and swap the device with a comparable device.
4. Turn on the system and the serial device.
If the problem persists, see Getting Help.
Troubleshooting A NIC
1. Run the appropriate diagnostic test. See Using System Diagnostics for available diagnostic tests.
2. Restart the system and check for any system messages pertaining to the NIC controller.
3. Check the appropriate indicator on the NIC connector:
If the link indicator does not light, check all cable connections.
If the activity indicator does not light, the network driver files might be damaged or missing.
Remove and reinstall the drivers if applicable. See the NIC documentation.
If applicable, change the autonegotiation setting.
Use another connector on the switch or hub.
4. Ensure that the appropriate drivers are installed and the protocols are bound. See the NIC documentation.
5. Enter the System Setup and confirm that the NIC ports are enabled on the Integrated Devices screen.
6. Ensure that the NICs, hubs, and switches on the network are all set to the same data transmission speed and
duplex. See the documentation for each network device.
7. Ensure that all network cables are of the proper type and do not exceed the maximum length.
If all troubleshooting fails, see Getting Help.
65

Table of Contents

Other manuals for Dell PowerEdge T20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge T20 and is the answer not in the manual?

Dell PowerEdge T20 Specifications

General IconGeneral
ChipsetIntel C226
Storage CapacityUp to 12TB
Power Supply290W
Form FactorTower
ProcessorIntel Xeon E3-1225 v3
MemoryUp to 32GB DDR3
Storage Options4 x 3.5-inch SATA
RAID SupportRAID 0, 1, 5, 10
Expansion Slots1 x PCIe x16
NetworkGigabit Ethernet
USB Ports4 x USB 3.0
Weight11 kg
Operating System SupportWindows Server, Red Hat Enterprise Linux
CPU OptionsIntel Xeon E3-1200 v3 series, Intel Core i3, Intel Pentium

Related product manuals