29
IP2368EN
EN
Display Description
CV - Display of total operations counter
→→→ → 182 manovre [esempio]
ENTER
CP - Display of partial operations counter
→→→ → 716 manovre [esempio]
ENTER
CH - Display of power supply hour counter
→→→
215 ore di funzionamento [esempio]
→
ENTER
CC - Cycle counters
11.7 Second level menu - CC (Cycles Counter)
Display Description
Selections
available
CA - Setting the maintenance alarm
(factory setting - alarm deactivated: 0.0 00. 00)
You can set the required number of operations (regarding the partial operations
counter) for signalling the maintenance alarm.
When the set number of operations is reached, the alarm message appears on
the display
.
Example: Setting the maintenance alarm after 700 operations (00) (07) (00)
ENTER ENTERUP DOWN
ENTER
2”
ENTER
→→
/
→→
UP DOWN
/
→→→→→→
OA - Selecting maintenance alarm display mode
00 - Visualisation on display (alarm message
)
01 - Visualisation on flashing light (with the automation idle, 4 flashes are made
and then repeated every hour) and on display (alarm message
).
02 - Visualisation on "open gate" indicator light (with the automation closed, 4
flashes are made and then repeated every hour) and on display (alarm message
).
ZP - Reset of partial operations counter
→
2”
ENTER
For correct functioning, you are advised to reset the partial operations counter:
- after maintenance work;
- after setting the maintenance alarm interval.
11.7.1 Additional configurable CC level parameters available with
→ enabled
CC - Cycle counters
716 operations [example]
182 operations [example]
215 operating hours [example]