OPERATION
L025317 Issue 5 July 2014 3-55
Test
Home > Settings > IO Port > Test
CAUTION: Setup for trained users and service technicians only.
The system may be damaged by incorrect settings.
All warranty is lost when the system is damaged by
incorrect settings.
Shows the status of inputs and outputs and allows setting / re-setting of
inputs and outputs.
Message Select
Home > Settings > IO Port > Message Select
Messages may be activated for printing by a combination of input signals
and a strobe signal via the user port. The input signals have to be set before
sending the message select strobe signal to the controller.
Select the message store and the messages to use.
To activate a message the sum of the binary representation value of the
inputs is used:
•User Input A - 1
•User Input B - 2
•User Input C - 4
•User Input D - 8
•User Input E - 16
•User Input F - 32
•User Input G - 64
Examples
If message 0 shall be printed set all user inputs low.
If message 1 shall be printed set user input A high and all other low.
If message 3 shall be printed set user input A and B high and all other low.
If message 13 shall be printed set user input A, C and D high and all other
low.