SOI/DT 2002-06 eb 17 599 35 27-25
4 Washing programmes charts
Key to programmes
Description
Calibration
Drain sub-phase for calibration of the electronic pressure switch
Levels
mm H
2
O
Level expressed in water mm (full/empty)
Pumps
OFF
Pump off
ON
Pump on
LEV
Pump on from one level of pressure switch
Water inlet valves
ELV2
Prewash
ELV3
Wash
ELV2 ELV3
Prewash + wash = softener
Refilling
NR
Normal refilling
VT
"Total exchange" refilling (virtual tank)
Dis
Refilling disabled
Time
‘
Minutes
“
Seconds
Tout
Max. time (timeout)
Drying
TMP
It is active up to the selected temperature
Motor movement
Code Pause(sec) Movement(sec) Speed (rpm.)
D_MOV
12 4 55
E_MOV
5 8 55
E1_MOV
4 12 75
SE_MOV
4 21 55/40
N_MOV
8 8 55
PWL1_MOV
40 1 35
PWL3_MOV
12 1 35
PWL4_MOV
57 1 35
COLD_MOV
4 12 40
DRY_MOV
57 3 55
CR3_MOV
Unidirectional movement 80
DLD_MOV
Unidirectional movement 40
OFF
No movement 0
SE_MOV Mov: