7.2 Button tips
For button tips, refer to Section 5.2.
7.3 Grand total reading (Gr TOTAL)
The grand total is a separate total that is not reset when the total is reset. This allows the
complete total to be tracked by the grand total, while individual batch, or daily totals are
reset regularly.
To display the grand total, press the Up/Display button. The display will read Gr TOTAL,
and the GT symbol will appear indicating the grand total is being displayed on the bottom
display. After 10 seconds, the bottom display will return to showing total. To lock the
grand total on the display, press Enter. Pressing Menu at any time will return to normal run
mode
Note
If the Display menu has been setup to display the grand total on the bottom display, pressing the Up/
Display button will display the maximum and minimum readings followed by the total.
7.4 Max/Min readings (MAXIMUM, MINIMUM)
The maximum and minimum (peak & valley) readings reached by the rate are stored in the
meter since the last reset or power-up. The meter shows MAXIMUM or MINIMUM to
differentiate between run mode and max/min display.
To display the maximum and minimum readings use Up/Display button to cycle the
bottom display. Maximum and minimum are displayed after the grand total.
Press the Enter button to remain in Max/Min display mode. If Enter is not pressed, the
Max/Min display readings will time out after ten seconds. The meter will return to display
the actual reading. Pressing Menu at any time will return to normal run mode.
Startup procedure
User manual 89