6 Product advanced features
Topics covered in this chapter:
•
Advanced features menu
•
Advanced features menu and display messages
•
Open collector outputs (OUTPUT)
•
Scaling the 4-20 mA analog output (Aout)
•
Gate function (GATE)
•
Contact debounce filter (FILTER)
•
Low-flow cutoff (CUTOFF)
•
Scaling and calibration (SCALCAL)
•
Total reset (T RESEt)
•
Set up passwords (PASSWRD)
•
Custom (CUSTOM)
•
System (SySTEM)
•
Serial communications (COMM)
•
Standby mode (STANDBy)
6.1
Advanced features menu
To simplify the setup process, functions not needed for most applications are located in
the Advanced features menu.
to access the Advanced features menu, press Enter inthe Advance menu in the Main Menu.
Refer to Section 5.5 for details.
Use the Advanced menu to select:
1. Open collector output configuration (OUTPUT)
2. Analog output configuration (A OUT)
3. Gate function for low speed inputs (GATE)
4. Set the input filter (FILTER)
5. Set low flow cutoff (CUTOFF)
6. Scale or live calibrate the meter and override K-Factor (SCALCAL)
7. Select method of total and grand total reset (T RESET)
8. Set passwords (PASSWRD)
9. Reconfigure the Main menu structure (CUSTOM)
10. Enter the System menu for meter settings and data logging (SySTEM)
11. Configure serial communication settings (COMM)
Product advanced features
User manual 53