Section 11: Engraving Machine Calibration /
Maintenance
163
In addition to the Config key, there are a couple of hidden calibration settings that are
accessed through the keys on the front control panel. These settings are accessed by
simultaneously pressing a two key combination. The two key combinations are
described below as well as the function to be set.
SETTINGS TWO KEY COMBINATION RANGE
Laser T.M. Reset + Up Range: 0 to 3
Activates laser tickle mode.
0 is off, 1 is most common if used.
Laser T.I. Reset + Down Range: 0 to 3
Activates laser tickle duration.
0 is off, 1 is most common if used.
Auto Delete Reset + Job Range: Yes or No
Automatically deletes every job after it has finished running or if the job is stopped and
Reset. The factory default is No.
Bed Size Reset + Config Range: 16 x 12, 24 x 12
Sets the bed size of your system. This setting should never need to be changed.
IP Address Go + Pointer
Set your IP Address using this key
combination. See the section for Setting IP
Address earlier in this manual.
Changing Calibration settings:
Press the two-key combination for the setting you want to change.
Increase or decrease the numerical value using the Up and Down keys. To speed
the process of changing a number, apply constant pressure to the Up or Down key
to change the number by units of ten. Single click to change by units of one.
Press the Go button. The setting is now changed.
If you want to just see what the setting is, but do not want to change it, press the
Stop button after you have viewed the calibration setting.