Syntax
[:SOURce]:SIMulation:NORMal 1:FREQuency
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:SIMulation:NORMal 1:FREQuency?
[MINimum|MAXimum]
Parameter/Return
parameter
1
Normal 1
<NR2>
Frequency of abnormal step
MINimum
Minimum frequency
MAXimum
Maximum frequency
Example
:SIM:NORM1:FREQ 60
Sets the frequency to 60Hz.
[:SOURce]:SIMulation:NORMal<1|2>
:PHASe:STARt:ENABle
Set
Query
Description
Enables/Disables (Fixed/Free) the ON Phs
parameter of the normal1 or normal2 step for the
Simulation mode.
Syntax
[:SOURce]:SIMulation:NORMal<1|2>:PHASe:STARt:E
NABle { <bool>|OFF|ON|FREE|FIXED}
Query Syntax
[:SOURce]:SIMulation:NORMal<1|2>:PHASe:STARt:E
NABle?
Parameter/Return
parameter
<1|2>
Normal 1 or Normal 2
OFF | 0 |
FREE
Disabled
ON | 1 |
FIXED
Enabled
Example
:SIM:NORM1:PHAS:STAR:ENAB 1
Enable the ON Phs.
[:SOURce]:SIMulation:NORMal<1|2>
:PHASe:STARt[:IMMediate]
Set
Query
Description
Sets or queries the ON Phs parameter of the
normal1 or normal2 step for the Simulation mode.

Table of Contents

Other manuals for GW Instek ASR-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek ASR-2000 Series and is the answer not in the manual?

GW Instek ASR-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelASR-2000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals