ASR-2000 Programming Manual
74
Return parameter
<NR1>
CONT
Continuous mode (normal operating
mode)
SEQ
Sequence mode
SIM
Simulation mode
:SYSTem:CONFigure:EXTio[:STATe]
Set
Query
Description
Sets or queries the external control state on/off.
Syntax
Query Syntax
:SYSTem:CONFigure:EXTio[:STATe] {<bool>|OFF|ON}
:SYSTem:CONFigure:EXTio[:STATe]?
Parameter
OFF | 0
Turns the external control off.
ON | 1
Turns the external control on.
Return parameter
<bool>
Returns the external control status.
:SYSTem:ERRor
Query
Description
Queries the error queue. The last error message is
returned. A maximum of 32 errors are stored in the
error queue.
Query Syntax
:SYSTem:ERRor?
Return parameter
<string>
Returns an error code followed by
an error message as a single string.
Example
SYSTem:ERRor?
-100, “Command error”
:SYSTem:ERRor:ENABle
Set
Query
Description
Clears the Error Queue and enables all error
messages to be placed in the System Error Queue.
Syntax
:SYSTem:ERRor:ENABle

Table of Contents

Other manuals for GW Instek ASR-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek ASR-2000 Series and is the answer not in the manual?

GW Instek ASR-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelASR-2000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals