ASR-2000 Programming Manual
86
[:SOURce]:VOLTage:LIMit:RMS
Set
Query
Description
Sets or queries the voltage limit for the continuous
operation mode. (Only AC-INT or AC-ADD or
AC-Sync Active)
Syntax
[:SOURce]:VOLTage:LIMit:RMS
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:VOLTage:LIMit:RMS?
[MINimum|MAXimum]
Parameter
<NR2>
Vrms.
MINimum
Minimum voltage limit
MAXimum
Maximum voltage limit
Return parameter
<NR2>
Returns the voltage limit.
Example
VOLT:LIM:RMS?
600.00
Returns the Vrms limit.
[:SOURce]:VOLTage:LIMit:HIGH
Set
Query
Description
Sets or queries the voltage high limit. (Only
AC+DC-INT or DC-INT or AC+DC-ADD or
AC+DC-Sync Active)
Syntax
[:SOURce]:VOLTage:LIMit:HIGH
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:VOLTage:LIMit:HIGH?
[MINimum|MAXimum]
Parameter
<NR2>
Voltage high limit
MINimum
Minimum voltage high limit
MAXimum
Maximum voltage high limit
Return parameter
<NR2>
Returns the voltage high limit.
Example
VOLT:LIM:HIGH?
500.00
Returns the voltage high limit.