54
MAX
9
Example
:DATA:SEQ:REC 1
Loads the data from Seq1.
:DATA|TRACe:SEQuence:STORe
Set
Description
Saves the sequence data. This command is the
equivalent to saving a sequence memory in
Sequence mode.
Syntax
:DATA|TRACe:SEQuence:STORe
{<NR1>|MINimum|MAXimum}
Parameter
<NR1>
0~9 (Seq0 ~ Seq9).
MIN
0
MAX
9
Example
:DATA:SEQ:STOR 1
Saves the data from Seq1.
:DATA|TRACe:SIMulation:CLEar
Set
Description
Clears the simulation data for the selected save
memory (SIM0 ~ SIM9).
Syntax
:DATA|TRACe:SIMulation:CLEar
{<NR1>|MINimum|MAXimum}
Parameter
<NR1>
0~9 (SIM0 ~ SIM9).
MIN
0
MAX
9
Example
:DATA:SIM:CLE 1
Clears the simulation data from SIM1.
:DATA|TRACe:SIMulation:RECall
Set
Description
Loads the simulation data. This command is the
equivalent to recalling a simulation memory in the
Simulation mode (SIM0~SIM9).