EasyManuals Logo
Home>GW Instek>Portable Generator>ASR-2000 Series

GW Instek ASR-2000 Series Programming Manual

GW Instek ASR-2000 Series
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #99 background imageLoading...
Page #99 background image
REMOTE CONTROL
99
:SIM:INIT:FREQ 60
Sets the frequency of the initial step to 60Hz.
[:SOURce]:SIMulation:INITial:PHASe:STARt
:ENABle
Set
Query
Enables/Disables (Fixed/Free) the ON Phs
parameter of the initial step for the Simulation mode.
[:SOURce]:SIMulation:INITial:PHASe:STARt:ENABle
{<bool>|OFF|ON|FREE|FIXED}
[:SOURce]:SIMulation:INITial:PHASe:STARt:ENABle?
OFF | 0 |
FREE
Disabled
ON | 1 |
FIXED
Enabled
:SIM:INIT:PHAS:STAR:ENAB 1
Enable the ON Phs.
[:SOURce]:SIMulation:INITial:PHASe:STARt
[:IMMediate]
Set
Query
Sets or queries the ON Phs parameter of the initial
step for the Simulation mode.
[:SOURce]:SIMulation:INITial:PHASe:STARt
[:IMMediate] {<NR2>|MINimum|MAXimum}
[:SOURce]:SIMulation:INITial:PHASe:STARt
[:IMMediate]? [MINimum|MAXimum]
<NR2>
ON Phs (start phase)
MINimum
0
MAXimum
359.9
:SIM:INIT:PHAS:STAR 0
Sets ON Phs to 0.

Table of Contents

Other manuals for GW Instek ASR-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek ASR-2000 Series and is the answer not in the manual?

GW Instek ASR-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelASR-2000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals