Example
:PHAS:STOP:STAT?
FIXED
Returns the state of stop phase as Fixed.
[:SOURce]:PHASe:STARt[:IMMediate]
Set
Query
Description
Sets or queries the start phase. (Not available for
DC-INT, AC+DC-EXT and AC-EXT)
Syntax
[:SOURce]:PHASe:STARt[:IMMediate]
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:PHASe:STARt[:IMMediate]?
[MINimum|MAXimum]
Parameter/Return
parameter
<NR2>
Start phase value
MINimum
0º
MAXimum
359 º
Example
:PHAS:STAR 0
Sets the starting phase to 0.
[:SOURce]:PHASe:STOP[:IMMediate]
Set
Query
Description
Sets or queries the off phase of the waveform. (Not
available for DC-INT, AC+DC-EXT and AC-EXT)
Note:
Sets the off phase of the waveform after the output
has been turned off.
Syntax
[:SOURce]:PHASe:STOP[:IMMediate]
{<NR2>|MINimum|MAXimum}
Query Syntax
[:SOURce]:PHASe:STOP[:IMMediate]?
[MINimum|MAXimum]
Parameter/Return
parameter
<NR2>
Stop phase value
MINimum
0 º
MAXimum
359 º
Example
:PHAS:STOP 60
Sets the stop phase to 60.

Table of Contents

Other manuals for GW Instek ASR-2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GW Instek ASR-2000 Series and is the answer not in the manual?

GW Instek ASR-2000 Series Specifications

General IconGeneral
BrandGW Instek
ModelASR-2000 Series
CategoryPortable Generator
LanguageEnglish

Related product manuals